hp5200 報錯50.6熱凝器錯誤,高壓板如何拆解?
更新時間:2025/4/3 22:22:44,view:2381hp打印機HP5200蘇州hp打印機售后服務中心客服熱線69616769,蘇州hp售后電話,hp售后網(wǎng)點,
hp5200 機器,報錯50.6熱凝器錯誤,經(jīng)查定影組件 未發(fā)現(xiàn)有問題,懷疑高壓板問題,蛤高壓小弟沒有拆過,求那么朋友說一下,怎么拆
hp常見故障問題解答 2010-10-8 20:58:36
硒鼓下面有兩顆長螺絲,兩邊有些螺絲
hp常見故障問題解答 2010-10-8 20:58:56
不是高壓板的問題,是電源板給高壓供電的問題。
hp常見故障問題解答 2010-10-8 20:59:14
50.X FUSER ERROR
A fuser error has occurred.
NOTE A fuser error might occur
because of inadequate power
supply, inadequate line voltage, or a
fuser problem.
X Description:
1 Low fuser temperature
2 Fuser-warmup service
3 High fuser temperature
6 Open fuser
7 Fuser pressure release mechanism failure
技術(shù) ShangriLa 發(fā)表于 2023/10/6 換個定影了

硒鼓下面有兩顆長螺絲,兩邊有些螺絲

不是高壓板的問題,是電源板給高壓供電的問題。

50.X FUSER ERROR
A fuser error has occurred.
NOTE A fuser error might occur
because of inadequate power
supply, inadequate line voltage, or a
fuser problem.
X Description:
1 Low fuser temperature
2 Fuser-warmup service
3 High fuser temperature
6 Open fuser
7 Fuser pressure release mechanism failure