理光1811L提示sc542代碼錯誤
更新時間:2025/3/7 20:08:00,view:717理光打印機1811L蘇州理光打印機售后服務(wù)中心客服熱線69616769,蘇州理光售后電話,理光售后網(wǎng)點, 理光1811l底版出現(xiàn)灰底, 理光mp1811l出現(xiàn)sc302, RICOHAficioMP1811L打印機出現(xiàn)SC322, 理光1811L處C542, 理光MP1811L更換碳粉后還提示缺少碳粉,維修視頻
理光1811 L提示sc542代碼錯誤
理光常見故障問題解答 2014-11-28 10:45:23
求助!
理光1811跳代碼 打印機修理王 2021/9/22 Code: SC542定影器故障
Description:
Fusing Reload Temperature Error (Fatal Error) (C8)
Causes:
After starting up , during operation the machine detected after 5 readings at 1.5 sec. intervals that the hot roller was 5 below the reload (operating) temperature. Unstable input voltage Fusing thermistor deformed , out of position Fusing lamp harness loose, broken, defective Fusing lamp defective Fusing unit defective
Remedy:
Use high quality power source Check the Fusing thermistor position , it harness connection Check the Fusing lamp , it harness connection Replace Fusing unit

求助!

Description:
Fusing Reload Temperature Error (Fatal Error) (C8)
Causes:
After starting up , during operation the machine detected after 5 readings at 1.5 sec. intervals that the hot roller was 5 below the reload (operating) temperature. Unstable input voltage Fusing thermistor deformed , out of position Fusing lamp harness loose, broken, defective Fusing lamp defective Fusing unit defective
Remedy:
Use high quality power source Check the Fusing thermistor position , it harness connection Check the Fusing lamp , it harness connection Replace Fusing unit