更新時間:2025/7/18 19:07:36,view:117蘇州東芝2006打印機(jī)售后服務(wù)中心客服熱線69616769,蘇州東芝打印機(jī)售后維修電話,東芝打印機(jī)售后網(wǎng)點(diǎn),東芝2006復(fù)印機(jī)出現(xiàn)請求維修C412,報ca020,維修代碼c260,打印機(jī)C413維修代碼,換粉盒顯示無粉,dp卡在加熱組件,打印機(jī)能不能加粉,復(fù)印機(jī)打印復(fù)出的資料有像黑灰一樣黑印,復(fù)印機(jī)一直顯示添加炭粉然后很響,錯誤代碼C970怎么回事,復(fù)印機(jī)錯誤代碼C260,dp驅(qū)動掃描組件未就緒怎么回事,復(fù)印機(jī)開機(jī)預(yù)熱出現(xiàn)異常響聲,字也越來越淡了,故障代碼C413,載體初始化值多少,2006維修視頻2025/7/18
東芝2006復(fù)印機(jī)請求維修c413代碼是多少
東芝2006進(jìn)紙卡紙 電源修理 2021/11/13 蘇州東芝2006售后維修服務(wù)中心地址查詢 Code C413
Description Fuser unit related service call. Thermistor abnormality during warming up, in ready status after abnormality judgment.
Causes MAIN board Thermistors Heater lamp
Remedy
1 Check the power voltage Check if the power voltage is normal. (Is the voltage during the operation ±10% of the rated voltage?)
2 Check the each elements of error status Check the abnormal thermistors 08-4570-0: Center thermistor 08-4570-1: Side thermistor 08-4570-2: Edge thermistor 08-4570-5: Error counter
3 Check the thermistors
1. Check if the connectors are disconnected.
2. Check if the center,edge thermistors are in contact with the surface of the fuser roller properly?
3. Check if the center,edge thermistors are not deformed, dirty.
4. Check if the harnesses of the center,edge thermistors are open circuited.
4 Check the heater
1. Check if the heater is broken.
2. Check if the connector of the heater is disconnected.
3. Check if the harnesses are connected properly to the terminals of the heater lamp.
4. Check if the thermostat is blown.
5 Check the MAIN board
1. Check if the connectors are disconnected.
2. Check if the conductor pattern on the MAIN board is short circuited, open circuited.
3. Replace the MAIN board.
6 Clear the status counter After repairing the matter which caused the error [C413 / C414], perform the following:
1. Turn ON the power while [0],[8] are pressed simultaneously.
2. Key in "2002", then press [START].
3. Change the current status counter value "1", "2" to "0", then press [OK] (to cancel [C413 / C414]).
4. Turn the power OFF,then back ON. Make sure that the equipment enters the normal ready state.

Description Fuser unit related service call. Thermistor abnormality during warming up, in ready status after abnormality judgment.
Causes MAIN board Thermistors Heater lamp
Remedy
1 Check the power voltage Check if the power voltage is normal. (Is the voltage during the operation ±10% of the rated voltage?)
2 Check the each elements of error status Check the abnormal thermistors 08-4570-0: Center thermistor 08-4570-1: Side thermistor 08-4570-2: Edge thermistor 08-4570-5: Error counter
3 Check the thermistors
1. Check if the connectors are disconnected.
2. Check if the center,edge thermistors are in contact with the surface of the fuser roller properly?
3. Check if the center,edge thermistors are not deformed, dirty.
4. Check if the harnesses of the center,edge thermistors are open circuited.
4 Check the heater
1. Check if the heater is broken.
2. Check if the connector of the heater is disconnected.
3. Check if the harnesses are connected properly to the terminals of the heater lamp.
4. Check if the thermostat is blown.
5 Check the MAIN board
1. Check if the connectors are disconnected.
2. Check if the conductor pattern on the MAIN board is short circuited, open circuited.
3. Replace the MAIN board.
6 Clear the status counter After repairing the matter which caused the error [C413 / C414], perform the following:
1. Turn ON the power while [0],[8] are pressed simultaneously.
2. Key in "2002", then press [START].
3. Change the current status counter value "1", "2" to "0", then press [OK] (to cancel [C413 / C414]).