施樂(lè)7550出現(xiàn)093-315是什么原因 ,093-315 RAP
BSD-ON:9.15 Toner Dispense Control (1 Of 3) BSD, CH9.16
Magenta Dispense failure.
Procedure
Enter the Diagnostics. Enter DC330 [093-007] (Magenta Dispense Motor). Start. Dispense
Motor is heard rotating. (ON duration is 2 sec.)
Y N
Open the PWB Chassis. (REP2.1.1) 24VDC is measured between P/J430-8 () on
the IOT PWB , GND (-).
Y N
Refer to BSD CH2.2, check the 24VDC circuit to P/J430-6 on the IOT PWB.
Turn off the power. Disconnect Connectors P/J201M on the Dispense Motor. Measure
the wire-wound resistance of the Dispense Motor. The resistance between P/J201M-1
, -2 pins is between 22.0 , 27.0 ohms.
Y N
Replace the Magenta Dispense Motor (PL6.4).
Check the following for continuity:
IOT PWB P/J436-A12 to Dispense Motor P/J201M-1
IOT PWB P/J436-A11 to Dispense Motor P/J201M-2
Every resistance is 1 ohm , less.
蘇州施樂(lè)打印機(jī)維修站電話(huà)696l6769,維修,售后服務(wù)
施樂(lè)7550打印漏墨 手機(jī)用戶(hù)220.19.*.* 2021-6-2 你好
BSD-ON:9.15 Toner Dispense Control (1 Of 3) BSD, CH9.16
Magenta Dispense failure.
Procedure
Enter the Diagnostics. Enter DC330 [093-007] (Magenta Dispense Motor). Start. Dispense
Motor is heard rotating. (ON duration is 2 sec.)
Y N
Open the PWB Chassis. (REP2.1.1) 24VDC is measured between P/J430-8 () on
the IOT PWB , GND (-).
Y N
Refer to BSD CH2.2, check the 24VDC circuit to P/J430-6 on the IOT PWB.
Turn off the power. Disconnect Connectors P/J201M on the Dispense Motor. Measure
the wire-wound resistance of the Dispense Motor. The resistance between P/J201M-1
, -2 pins is between 22.0 , 27.0 ohms.
Y N
Replace the Magenta Dispense Motor (PL6.4).
Check the following for continuity:
IOT PWB P/J436-A12 to Dispense Motor P/J201M-1
IOT PWB P/J436-A11 to Dispense Motor P/J201M-2
Every resistance is 1 ohm , less.