佳能6075代碼e000065-0001
更新時間:2025/7/14 10:51:56,view:118蘇州佳能6075打印機售后服務中心客服熱線69616769,蘇州佳能打印機售后維修電話,佳能打印機售后網(wǎng)點, 佳能6075出E000005-001, 佳能6075復印機怎么進去維修, 佳能6075E00006-0001, 佳能6075顯示時間, 佳能ir6075維護和故障排除,6075維修視頻2025/4/22
佳能6075代碼e000065-0001
技術 D7000 發(fā)表于 2022/3/16 佳能6075 Code E065-0001
Description Error in detection of abnormal M charging AC current value
During the paper interval simple discharge current control, a current value that is higher than the target of
500[uA] is detected
Remedy Error in output of charging high voltage, Drum Unit error , environment control error
1. COPIER > DISPLAY > ANALOG; check if the TEMP value , the HUM value are matched with the environment temperature. When the values are dramatically mismatched (Lager than
15degrees Celsius)
2-1. Check the harness , connector between the DC Controller (UN09/ J206) , the Environment Sensor (UN45)
3-1. Replace the Environment Sensor (UN45)
4-1. Replace the DC Controller (UN9) When the values are matched
2-2. Check the state of the charging high voltage contact point
3-2. Replace the Drum Unit (M)
4-2. Check the harness , connector between the DC Controller PCB (UN09/ J21) , the Primary Charging High Voltage PCB (UN06/ J441, J442)
5-2. Replace the Primary Charging High Voltage PCB (UN06)
6-2. Replace the DC Controller PCB (UN09)

Description Error in detection of abnormal M charging AC current value
During the paper interval simple discharge current control, a current value that is higher than the target of
500[uA] is detected
Remedy Error in output of charging high voltage, Drum Unit error , environment control error
1. COPIER > DISPLAY > ANALOG; check if the TEMP value , the HUM value are matched with the environment temperature. When the values are dramatically mismatched (Lager than
15degrees Celsius)
2-1. Check the harness , connector between the DC Controller (UN09/ J206) , the Environment Sensor (UN45)
3-1. Replace the Environment Sensor (UN45)
4-1. Replace the DC Controller (UN9) When the values are matched
2-2. Check the state of the charging high voltage contact point
3-2. Replace the Drum Unit (M)
4-2. Check the harness , connector between the DC Controller PCB (UN09/ J21) , the Primary Charging High Voltage PCB (UN06/ J441, J442)
5-2. Replace the Primary Charging High Voltage PCB (UN06)
6-2. Replace the DC Controller PCB (UN09)
熱門圖文