技術(shù) ghostwindows30 發(fā)表于 2023/5/6 Code C413 定影故障熱敏電阻檢測(cè)到異常
Description Fuser unit related service call. Thermistor abnormality during warming up , in ready status after abnormality judgment.
Causes MAIN board Thermistors Heater lamp
Remedy
1 Check the power voltage Check if the power voltage is normal. (Is the voltage during the operation ±10% of the rated voltage?)
2 Check the each elements of error status Check the abnormal thermistors 08-4570-0: Center thermistor 08-4570-1: Side thermistor 08-4570-2: Edge thermistor 08-4570-5: Error counter

Description Fuser unit related service call. Thermistor abnormality during warming up , in ready status after abnormality judgment.
Causes MAIN board Thermistors Heater lamp
Remedy
1 Check the power voltage Check if the power voltage is normal. (Is the voltage during the operation ±10% of the rated voltage?)
2 Check the each elements of error status Check the abnormal thermistors 08-4570-0: Center thermistor 08-4570-1: Side thermistor 08-4570-2: Edge thermistor 08-4570-5: Error counter