美能達(dá)維修召喚c3852
更新時(shí)間:2025/7/12 13:35:37,view:210蘇州美能達(dá)3852打印機(jī)售后服務(wù)中心客服熱線69616769,蘇州美能達(dá)打印機(jī)售后維修電話,美能達(dá)打印機(jī)售后網(wǎng)點(diǎn),美能達(dá)3852 C, 出代碼c-, 復(fù)印機(jī)出現(xiàn)C, 故障代碼如何清除, 維修召喚, 柯尼卡C300出現(xiàn)C如何清除, 維修C, 報(bào)錯(cuò), 達(dá)復(fù)印機(jī)顯示機(jī)器故障C是什么意思, 故障代碼, 350錯(cuò)誤C, BH250出現(xiàn)C, 350出現(xiàn), 195C怎么解決,3852維修視頻2025/5/4
美能達(dá)維修召喚c3852
美能達(dá)c350售后技術(shù)論壇 不離不棄 2018/10/9 13:25:35 350C5832是什么意思,怎么解決。。。。。
美能達(dá)c350售后技術(shù)論壇 韓室絞 2018/10/10 22:02:13 Code C3852
Description Low Fuser Temperature Failure (Sub)
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below
105 °C during standby.
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below
105 °C during printing.
Remedy
1 Check that the H1 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary.
2 Check that the H2 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary.
3 Check the installation of the TH1 and the TH2, and correct or clean as necessary.
4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity.
5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity.
6 Check the continuity of the H1. Correct or replace as necessary.
7 Check the continuity of the H2. Correct or replace as necessary.
8 Change PU1.
9 Change PWB-A.


Description Low Fuser Temperature Failure (Sub)
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below
105 °C during standby.
- The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below
105 °C during printing.
Remedy
1 Check that the H1 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary.
2 Check that the H2 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary.
3 Check the installation of the TH1 and the TH2, and correct or clean as necessary.
4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity.
5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity.
6 Check the continuity of the H1. Correct or replace as necessary.
7 Check the continuity of the H2. Correct or replace as necessary.
8 Change PU1.
9 Change PWB-A.
熱門(mén)圖文